Optris CTlaser G5 Infrared Pyrometers
The Optris CTlaser dual laser sensors offer a greater degree of flexibility in available options. The electronics are housed in a remote enclosure with a selection of output and digital interface options. The electronic box also includes its own digital LCD display showing temperature and alarm conditions. All configuration options are set via the front panel removing the need to use a PC to configure the pyrometer. Shorter wavelength versions are also available specifically designed for use with metals, glass and plastic films. All Optris CTlaser pyrometers come with a choice of optics to best suit your requirement.
[learn_more caption=”Features” state=”open”]
Accurate glass temperature measurements on flat glass lines, container glass machines, bulb manufacturing and car glass finishing |
Temperature ranges from 100°C to 1650°C, measuring spots up from 1.0 mm and response times up from 10 ms |
Double laser aiming marks real spot size and location at any distance |
Cooling and protection accessories for harsh environmental conditions |
Usable up to 85°C ambient temperature without cooling and automatic laser switch off at 50°C |
[/learn_more]
[learn_more caption=”General Specifications” state=”close”]
Environmental rating: | IP 65 (NEMA-4) |
Ambient temperature: | Sensing Head: -20°C to 85°C (50°C with laser ON) Electronics: 0 – 85°C |
Storage temperature: | Sensing Head: -40°C to 85°C Electronics: -40 – 85°C |
Relative humidity: | 10 – 95%, non condensing |
Vibration: | IEC 68-2-6: 3 G, 11-200 Hz, any axis |
Shock: | IEC 68-2-27: 50 G, 11 ms, any axis |
Weight: | Sensing Head: 600g Electronics: 420g |
[/learn_more]
[learn_more caption=”Measurement Specifications” state=”close”]
Temperature range (1): | 100°C – 1200°C (G5L) 250°C – 1650°C (G5H) 200°C – 1450°C (G5HF) 400°C – 1650°C (G5H1F) (scaleable via programming keys or software) |
Spectral range: | 5.0 μm |
Optical resolution (90 % energy): |
45:1 |
System accuracy: | ± 1% or ± 1,5°C (1)(2) (at ambient temperature 23 ±5°C) |
Repeatability: | ±0.5% or ±0.5°C (2) (at ambient temperature 23 ±5°C) |
Temperature resolution (digital): | 0.1K |
Response time (90%) (3): | 10 ms (G5HF, G5H1F) 80 ms (G5H) 120 ms (G5L) (90 %) |
Emissivity/Gain : |
0.100 – 1.100 (adjustable via programming keys or software) |
Transmissivity : |
0.100 – 1.100 (adjustable via programming keys or software) |
Signal processing: | peak hold, valley hold, average; extended hold function with threshold and hysteresis |
Software: | optris Compact Connect |
1) whichever is greater
2) ε = 1, exposure time 1 s
3) with dynamic adaptation at low signal levels
[/learn_more]
[learn_more caption=”Electrical Specifications” state=”close”]
Output/analogue: | Channel 1: 0/4 – 20 mA, 0-5/10 V, thermocouple J, K Channel 2: sensing head temperature (-20 – 85°C as 0-5 V or 0-10 V), alarm output |
Alarm output: | Open – collector (24 V / 50 mA) |
Optional: | relay: 2 x 60 V DC/42 V ACeff; 0.4 A; optically isolated |
Output/ digital: | uni-/ bidirectional, 9.6 kBaud, 0-3 V Level, USB optional |
Outputs/digital (optional): | USB, RS232, RS485, CAN, Profibus DP, Ethernet |
Output impedances: | mA max. 500ohms (with 5 – 36 V DC) mV min. 100 kohms load impedance thermocouple 20ohms |
Inputs: | Programmable functional inputs for external emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions) |
Cable length: | 3m (standard), 8 m, 15 m |
Current draw: | max. 160 mA |
Power supply: | 8 – 36 V DC |
Laser 635 nm: | 1mW, ON/OFF via electronic box or software |
[/learn_more]