TTR200 / TTR200X Temperature Transmitter for Pt100 Sensors, with calibration and linearisation features.

The TTR200 is our mid range transmitter for RTD or Slidewire sensors. It can accept many different types of RTD sensor such as Pt100, 500, 1000 etc and slidewire sensors up to 100K Ohm.
This product has a calibration feature where the output can be matched to the sensor on the input. It can be matched at zero, or both zero and span ends of the temperature range being measured. This is typically used when the product is being supplied with a calibration certificate matched to a particular temperature probe.
It is also possible to measure linear resistance up to 10K Ohms and slidewire sensors up to 100K Ohms.  The software allows a user linearisation function to be downloaded into the product. This allows the user to adapt the output to suit a non linear tank for example.
The TTR200X offers an excellent value ATEX approved version of the same transmitter for use in hazardous areas.
However, if you already know the specification you require, we can  configure the product for you at no extra cost.

Features

Suitable for RTD, Slidewire and Resistance Sensors
Sensor Calibration Feature
Adjustable Input Filter
ATEX and IECEx Approved Version
Gost Certificate
Sine Vibration Certificate
Can be supplied fitted to our temperature sensors.

Specifications @ 20°C

INPUT:
Standard RTD : PT100,PT500,PT1000, Cu100, Cu1000, Ni100, Ni120, Ni1000, Cu53, library.
Slide wire: Pot range (1 to 100) KΩ, Signal (0 to 100) %, accuracy 0.1 %
Resistance: (10 to 500) Ω ± 0.055 Ω, (500 to 2500) Ω ± 0.5 Ω, (2500 to 10500) Ω ±10.0 Ω.
Thermal Drift: (0 to 500) Ω 0.013 Ω/°C,(500 to 2500) Ω 0.063 Ω/°C, (2500 to 10500) Ω 0.27 Ω/°C
Excitation current: < 200 uA
Lead effect: Max lead resistance 20 Ω per leg, Effect 0.002 °C / Ω.
OUTPUT:
Output Type: 2 wire, 4 to 20mA current loop.
Output range: 4.0 to 20.0mA
Output Connection : Screw terminal
Maximum output: 21.5mA (in high burnout condition)
Minimum output: 3.8 mA Downscale Burnout
Accuracy: (mA Out/ 2000) or 5 uA which ever is the greater, Drift 1 uA/°C
Loop Voltage effect: ±0.2 uA/ V .
Thermal drift: ±2 uA / °C
Maximum output load: TTR200 [(Vsupply-10)/20] K Ohms(Example 700 Ohms @ 24 V)

General Specifications

Update time: 160ms
Response Time: 500ms
Start up time: 5 seconds
Warm-up time: 2 minutes to full accuracy
Power Supply : 10 to 30 Volts dc
Ambient operating range: TTR200(-40 to 85) °C ; (10 to 90) %RH (non condensing)TTR200X Refer to user manual
Ambient storage temperature: -50 to +90°C.
Ambient humidity range: 10 to 90% RH non condensing
Dimensions: 43 mm diameter; 21 mm height.
Weight: 31 g (encapsulated).
APPROVALS:
EMC – BS EN 61326: Electrical equipment for measurement control and laboratory use.
User Interface:
Type: USB 2.0.
Baud rate: 1200 baud.
Equipment: PC running windows XP or later, USB configurator.

Mechanical Drawing

TTR200 Mechanical Drawing

Electrical Drawing

TTR200 Mechanical Drawing